What is a Development Control Plan?

    A Development Control Plan provides detailed planning and design guidelines to support the planning controls in the Local Environmental Plan developed by a council. Each council is required to publish their Development Control Plan/s on the Planning Portal. 


    You can view Development Control Plan/s here.

    Why are you changing the Huntlee Development Control Plan?

    The State Government remains the Consent Authority for the Huntlee Major Project Approval  and any modifications to it. The Major Project Approval essentially relates to the subdivision, which includes the lot layout, at Huntlee. Council is responsible for the Huntlee DCP chapter and ensuring the plan provides adequate controls to manage development outcomes within residential and commercial allotments at Huntlee.

    The State Government has approved Modification 20 of the Huntlee Major Project Approval. Among other things, Modification 20 amends the Huntlee subdivision layout to create an additional 185 residential allotments within sub-stages TC2, TC3 and TC5 of the development (see picture below). The Huntlee developer anticipates that the residential allotments will provide for a medium density housing format within the Huntlee Town Centre, known as the ‘Urban One’ Lot Type. The Urban One Lot Type is a reference by the developer to a smaller, residential allotment, (i.e. between 217m2 and 354m2). The Urban One Lot Type will accommodate compact dwelling types, which will have the appearance of medium density residential.

    What will the changes do?

    To support the new medium density housing format, the developer of Huntlee, has approached

    Council requesting an amendment to the Huntlee DCP chapter to incorporate development

    controls for the new Lot Type. The key controls proposed in relation to the new Lot Type are

    listed in Table 1 below.

    ElementControl

    Site Coverage

    (maximum)

    70% of site area

    Landscape Area

    (minimum)

    20% of site area

    Minimum dimension 1

    Private Open

    Space (minimum)

    20% of site area

    Minimum dimension 1.5m

    Includes balconies and terraces

    Principal Private

    Open Space

    (minimum)

    16m2 per dwelling

    Minimum dimension 3m

    Front Setback

    (minimum)

    • 1.5m to building line

    • 1m articulation zone

    • 3m to garage

    Corner Lot

    Secondary Street

    Setback (minimum)

    1m single storey

    2m second storey and above

    Side Setback

    (minimum)

    900mm

    Nil side setback required on one side for lots less than or

    equal to 12m wide

    Nil side setback permitted to both sides for rear-loaded

    (laneway) lots less than or equal to 10m wide.

    Length of Zero Lot

    Line Wall

    (maximum)

    50% of lot length

    Articulation of zero lot walls must be a minimum of 450mm

    deep and 3m long

    Articulated areas must be accessible for maintenance

    Rear Setback

    (minimum)

    1.5m for single storey elements

    3m for two storey elements

    Nil for detached garages (and associated garage-top “Fonzie

    flats”) abutting laneways

    900mm for ancillary structures such as pools and outbuildings

    Car Parking

    Spaces (minimum)

    1
    Garages

    Double garage doors on street frontages permitted only for

    lots with a width of 10m or over

    For lots with 10m or less frontage, double garage doors on

    street frontages are only permitted if;

    • the building is at least 2 storeys, and

    • there is a projecting balcony above for the full width of

    the garage.

    Pools and Garden

    Structures

    Garden structures and/or a swimming pool and all associated

    pipework are to be wholly contained within the lot boundaries.

    Floor to Ceiling

    Height

    A minimum 2750mm floor to ceiling height is required for all

    ground floor and single storey dwellings.